Figure 23. Uni-Directional Trap Gate System
(external Swing gate opens out).
* WARNING
If Radio is used, gate system becomes bi-directional, compromising safety and security.
Gate
Operator
Master
Gate
Operator
Slave
Exit Loop
Swing gate open
direction and its
maximum arc.
Inside Interrupt Loop
Inside Interrupt Loop
Outside Interrupt Loop
Outside Interrupt Loop
Slide or Barrier Gate
Swing Gate
Additional
Master Wiring
(if needed):
Fire
Manual Inputs
Interrupt Bar
Photo-Sensors
MagLock
Tel . L ine
Additional
Slave Wiring
(if needed):
Interrupt Bar
Photo-Sensors
MagLock
1398F19
Master/
Slave
Cable
Shadow Loop
Can use Radio* or Cycle if
Exit Loop is not used.